Home  ■  Protocols

Recommended protocol Run B12 2011
Hillerød, DK

PR (PgR 636)

Protocol provided by

 
  laboratory Dept. Pathology
  hospital/institution Nordsjællands Hospital Hillerød, Hillerød, Denmark
  e-mail address lith@hih.regionh.dk
Primary antibody  
  clone PgR 636
  producer Dako
  product no., lot no. M3569, NS
  dilution 1:125
  diluent buffer and additive(s) Antibody diluent, Bond
  incubation time/temp. 15 min./RT
Epitope retrieval, HIER  
  device Bond-max
  buffer type, pH Bond Epitope Retrieval Sol. 2, pH 9
  warm-up/heating max/resting time 10 min./20 min./10 min.
  maximum heating temp. 100ºC
Visualization system  
  method 3-step polymer conjugate
  producer, product no. Leica Microsystems, DS9800
  incubation time/temp. 8 min +8 min./RT
Chromogen  
  type DAB
  producer, product no. Leica Microsystems, DS9800
  incubation time/temp. 10 min./RT
  enhancement, type NS
Immunostainer  
  type Bond-max™, Leica Microsystems
     
Abbreviations  
  HIER: heat induced epitope retrieval, MWO: microwave oven, NS: not stated, RT: room temperature
Disclaimer  
  NordiQC makes every attempt to provide accurate and up-to-date information, yet NordiQC does not make any claim or warranty regarding the accuracy of the provided information nor does it represent that the contents of the web site and protocols reflect the most recent developments in immunohistochemistry at any point in time.
 
SN/CJ

Last update 01-12-2011