Home  ■  Protocols

Recommended protocol Run 23 2008
Wien, AT

Ep-CAM (MOC-31)

Protocol provided by

 
  laboratory Pathologie
  hospital/institution Donauspital Wien, Austria
  e-mail address angelika.reiner@wienkav.at
Primary antibody  
  clone MOC-31
  producer Novocastra
  product no., lot no. Ncl-MOC31, 214307
  dilution 1:20
  diluent buffer and additive(s) Ventana
  incubation time/temp. 32 min./37ºC
Epitope retrieval, HIER  
  device Pressure cooker
  buffer type, pH TRS S1699, Dako, pH 6,1
  warm-up/heating max/resting time 25 min./5 min./25+20 min.
  maximum heating temp. 125ºC
Visualization system  
  method Lab. streptavidin-biotin
  producer, product no. Ventana, iView 760-091
  incubation time/temp. 2x8 min./37ºC
Chromogen  
  type DAB
  producer, product no. Ventana, iView 760-091
  incubation time/temp. 8 min./37ºC
  enhancement, type NS
Immunostainer  
  type Ventana Nexes
     
Abbreviations  
  HIER: heat induced epitope retrieval, MWO: microwave oven, NS: not stated, RT: room temperature
Disclaimer  
  NordiQC makes every attempt to provide accurate and up-to-date information, yet NordiQC does not make any claim or warranty regarding the accuracy of the provided information nor does it represent that the contents of the web site and protocols reflect the most recent developments in immunohistochemistry at any point in time.
 
SN/AS

Last update 01-07-2008