Home  ■  Protocols

Good Protocol Run 11 2004
Sundsvall, SE

CD31 (JC/70A)

Protocol provided by

 
  laboratory Avd Patologi och Cytologi
  hospital/institution Sundsvall sjukhus, Sweden
  e-mail address elisabet.gagner@lvn.se
Primary antibody  
  clone JC/70A
  producer DakoCytomation
  product no., lot no. M0823, 028
  dilution 1:25
  diluent buffer and additive(s) Ventana Ab diluent
  incubation time/temp. 32 min./42ºC
Epitope retrieval, HIER  
  device Benchmark
  buffer type, pH Tris-EDTA/EGTA, pH 9
  max. temp./max. temp. time 100ºC/28 min.
  total heating time/resting time NS
Visualization system  
  method Lab. streptavidin-biotin
  producer, product no. Ventana K760-091
  incubation time/temp. 8 + 8 min./42ºC
Chromogen  
  type iView-DAB
  producer, product no. Ventana K760-091
  incubation time/temp. 8 min./42ºC
  enhancement, type NS
Immunostainer  
  type Ventana Benchmark
     
Abbreviations  
  HIER: heat induced epitope retrieval, MWO: microwave oven, NS: not stated, RT: room temperature
Disclaimer  
  NordiQC makes every attempt to provide accurate and up-to-date information, yet NordiQC does not make any claim or warranty regarding the accuracy of the provided information nor does it represent that the contents of the web site and protocols reflect the most recent developments in immunohistochemistry at any point in time.
 
SN/AS

Last update 10-06-2004